Fujitsu PRIMERGY TX150 S6 Service Supplement Manual - Page 35

Browse online or download pdf Service Supplement Manual for Server Fujitsu PRIMERGY TX150 S6. Fujitsu PRIMERGY TX150 S6 45 pages.
Also for Fujitsu PRIMERGY TX150 S6: Notes On Using (8 pages)

Fujitsu PRIMERGY TX150 S6 Service Supplement Manual
Replacement routines
4.10

Replacing the system board

I
The system board is optional equipped with a TPM (Trusted Platform
Module) by the manufacturer. This module enables programs from third
party manufacturers to store key information (e.g. drive encryption using
Windows Bitlocker Drive Encryption).
The TPM is activated via the BIOS system (for more information, refer to
the Fujitsu Siemens Computers BIOS manual).
V
CAUTION!
– Before replacing the system board, ask your customer if he is using
the TPM functionality.
– If the customer is using the TPM functionality, advise him that he must
provide you with the TPM backup copies. For security reasons, the
TPM must be restored/re-saved by the customer.
If the customer DOES NOT have a backup copy, inform him that
replacing the system board will cause him to lose all his data.
Ê Open the server as described in the
Ê Lay the server on a table with the uncovered side facing upward. Place the
server in such a way that the feet can project over the edge.
Ê Remove all external cables.
Ê Remove all controllers from their slots (for a description see the Operating
Manual and the Options Guide). Take note of the slots of the controllers and
the cabling.
Ê Remove the system fan (for a description see the Options Guide).
Ê Remove the processor (see the
page
30).
Ê Remove the memory modules (for a description see the Options Guide).
Ê Remove all cables which may be connected to the system board.
TX150 S6
section "Preparation" on page
section "Replacing the processor" on
Service Supplement
Replacing the system board
17.
35