Fujitsu SPARC Enterprise M5000 Product Notes - Page 34

Browse online or download pdf Product Notes for Server Fujitsu SPARC Enterprise M5000. Fujitsu SPARC Enterprise M5000 44 pages. Rci build procedure
Also for Fujitsu SPARC Enterprise M5000: Features Manual (30 pages), Supplementary Manual (36 pages), Getting Started Manual (4 pages)

Fujitsu SPARC Enterprise M5000 Product Notes
Specific Issues and Workarounds Concerning Solaris (Continued)
TABLE 7
CR ID
Description
6522433
After the CPU hardware error occurred, the
fmdump(1M) command on the domain may
display an incorrect faulty component.
6527811
The showhardconf(8) command on the XSCF
cannot display PCI card information that is
installed in External I/O Expansion Unit, if the
External I/O Expansion Unit is configured
using PCI hotplug.
6530178
DR addboard(8) command can hang. Once
problem is observed, further DR operations
are blocked. Recovery requires reboot of the
domain.
6530178
DR addboard(8) command can hang. Once
problem is observed, further DR operations
are blocked. Recovery requires reboot of the
domain.
6530178
DR addboard(8) command can hang. Once
problem is observed, further DR operations
are blocked. Recovery requires reboot of the
domain.
6529714
Warning messages occur while trying to
configure more than four X4447A-Z or
X1027A-Z1 cards into one I/O Boat.
6530178
DR addboard(8) command can hang. Once
problem is observed, further DR operations
are blocked. Recovery requires reboot of the
domain.
6530178
DR addboard(8) command can hang. Once
problem is observed, further DR operations
are blocked. Recovery requires reboot of the
domain.
6530288
Ap_Id format may not be shown correctly by
cfgadm(1M) command.
6530753
Some of the PCI slots in the External I/O
Expansion Unit PCI slots are not displayed
during a normal boot operation.
6531036
The error message network
initialization failed can appear
repeatedly after boot net installation.
24
SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1060 • February 2008
Workaround
Check system status on XSCF.
Check for the patch 128346-01 for this detect.
There is no workaround.
This bug has been fixed in Solaris 10 8/07.
There is no workaround.
This bug has been fixed in Solaris 10 8/07.
There is no workaround.
This bug has been fixed in Solaris 10 8/07.
No workaround available at this time.
There is no workaround.
This bug has been fixed in Solaris 10 8/07.
There is no workaround.
This bug has been fixed in Solaris 10 8/07.
None available at this time.
This bug has been fixed in Solaris 10 8/07.
Use one of the following operations to display
all of the PCI slots.
• boot -r (at open boot prompt)
• devfsadm -C (at Solaris prompt)
• cfgadm (twice at Solaris prompt)
There is no workaround.