Fujitsu SPARC Enterprise M8000 Product Notes - Page 38
Browse online or download pdf Product Notes for Server Fujitsu SPARC Enterprise M8000. Fujitsu SPARC Enterprise M8000 44 pages. For xcp version 1041
Also for Fujitsu SPARC Enterprise M8000: Getting Started Manual (4 pages), Features Manual (30 pages), Supplementary Manual (36 pages)
Specific Issues and Workarounds Concerning Solaris (Continued)
TABLE 6
CR ID
Description
6542632
Memory leak in PCIe module if driver attach
fails.
6545685
If the following message displayed on the OS
console, memory degradation or XSB
deconfiguration may occur in the subsequent
reboot.
Example:
mc-opl: WARNING: mc-opl rewrite timeout on
/LSB0/B0
6546188
The system panics when running hotplug
(cfgadm) and DR operations (addboard and
deleteboard)on the following cards:
• X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
• X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
6551356
The system panics when running hotplug
(cfgadm) to configure a previously
unconfigured card. The message "WARNING:
PCI Expansion ROM is not accessible" will be
seen on the console shortly before the system
panic. The following cards are affected by this
defect:
• X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
• X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
6556742
The system panics when DiskSuite can not
read the metadb during DR. This bug affects
the following cards:
• SG-XPCIE2FC-QF4, 4Gb PCI-e Dual-Port
Fibre Channel HBA
• SG-XPCIE1FC-QF4, 4Gb PCI-e Single-Port
Fibre Channel HBA
• SG-XPCI2FC-QF4, 4Gb PCI-X Dual-Port
Fibre Channel HBA
• SG-XPCI1FC-QF4, 4Gb PCI-X Single-Port
Fibre Channel HBA
28
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1041 • October 2007
Workaround
There is no workaround. Check for the
availability of a patch for this defect.
Add the following to /etc/system and then
reboot the domain:
set mc-opl: mc_max_rewrite_loop =
10000
There is no workaround. Check for the
availability of a patch for this defect.
Perform cfgadm -c disconnect to
completely remove the card. After waiting at
least 10 seconds, the card may be configured
back into the domain using the cfgadm -c
configure command.
Panic can be avoided when a duplicated copy
of the metadb is accessible via another Host
Bus Adaptor. Or you can apply patch 125166-
06.