Fujitsu SPARC Enterprise T2000 Product Notes - Page 23

Browse online or download pdf Product Notes for Server Fujitsu SPARC Enterprise T2000. Fujitsu SPARC Enterprise T2000 28 pages.
Also for Fujitsu SPARC Enterprise T2000: Getting Started Manual (2 pages), Getting Started Manual (12 pages), Product Notes (30 pages)

Fujitsu SPARC Enterprise T2000 Product Notes
During system operation, an event may repeatedly occur that the server internal fan
shows the failed state (log: "SYS_FAN at FT0/FMx has FAILED.") and then gets
back to normal (log: "SYS_FAN at FT0/FM1 is OK.") one second later.
Output example (Excerpt from the showlogs command result of ALOM):
JAN 26 15:36:25: 00040066: "SYS_FAN at FT0/FM1 has FAILED."
JAN 26 15:36:26: 00040065: "SYS_FAN at FT0/FM1 is OK."
JAN 31 06:11:56: 00040066: "SYS_FAN at FT0/FM1 has FAILED."
JAN 31 06:11:57: 00040065: "SYS_FAN at FT0/FM1 is OK."
FEB 12 01:59:20: 00040066: "SYS_FAN at FT0/FM1 has FAILED."
FEB 12 01:59:21: 00040065: "SYS_FAN at FT0/FM1 is OK."
FEB 13 22:12:24: 00040066: "SYS_FAN at FT0/FM1 has FAILED."
FEB 13 22:12:25: 00040065: "SYS_FAN at FT0/FM1 is OK."
FEB 13 22:39:20: 00040066: "SYS_FAN at FT0/FM2 has FAILED."
FEB 13 22:39:21: 00040065: "SYS_FAN at FT0/FM2 is OK."
FEB 15 23:38:34: 00040066: "SYS_FAN at FT0/FM2 has FAILED."
FEB 15 23:38:35: 00040065: "SYS_FAN at FT0/FM2 is OK."
Or, the "FAILED" status may repeatedly appear as below.
Output example (Excerpt from the showlogs command result of ALOM):
AUG 24 05:05:09: 00040066: "SYS_FAN at FT0/FM0 has FAILED."
AUG 24 05:08:21: 00040066: "SYS_FAN at FT0/FM1 has FAILED."
AUG 24 05:09:35: 00040066: "SYS_FAN at FT0/FM2 has FAILED."
AUG 24 05:47:41: 00040066: "SYS_FAN at FT0/FM0 has FAILED."
AUG 24 05:50:40: 00040066: "SYS_FAN at FT0/FM0 has FAILED."
AUG 24 06:11:53: 00040066: "SYS_FAN at FT0/FM1 has FAILED."
AUG 24 06:55:30: 00040066: "SYS_FAN at FT0/FM2 has FAILED."
AUG 24 07:30:58: 00040066: "SYS_FAN at FT0/FM0 has FAILED."
AUG 24 07:36:15: 00040066: "SYS_FAN at FT0/FM0 has FAILED."
AUG 24 07:45:20: 00040066: "SYS_FAN at FT0/FM1 has FAILED."
In each case, the showfaults and the showenvironment command results are
normal.
Important Information About the SPARC Enterprise T2000 Server
15