Appendix2
ARNI N G
When operating the scanner, the ADF's inside glass
becomes very hot.
Before you clean inside the scanner, turn off its power
and unplug the AC adapter from the outlet. Wait for at
least 15 minutes.
Turn on the scanner when you clean the Feed rollers
or Eject rollers.
■ Cleaning Materials
Cleaning
Parts
Materials
Number
Cleaner F1
PA03950-
0352
Cleaning wipe
PA03950-
0419
Lint-free dry cloth - Commercially available one
*1: For details about the cleaning materials, contact the
FUJITSU scanner dealer where you purchased the
scanner.
*2: Pre-moistened with Cleaner F1, Cleaning Wipes are
used instead of moistened cloths.
■ Cleaning Method
The ADF must be cleaned with a lint-free cloth moistened
with the Cleaner F1.
ATTENTION
It may take long before the cleaner vaporizes if a large
quantity is used. When cleaning the scanner parts,
dampen a cloth with modest quantities of the cleaner. In
addition, wipe off the cleaner completely with a soft lint-
free cloth to leave no residue on the surface of the
cleaned parts.
AP-2
DAILY CARE
Remarks
1 bottle
Moisten the cloth with
this fluid and wipe the
scanner clean. (*1)
24 sheets per pack
(*1)(*2)
■ Locations and Cycle for Cleaning
Part to clean
Brake Roller
Pick roller
Feed rollers
Plastic rollers
Eject rollers
Glass
ATTENTION
The scanner must be cleaned more frequently if you scan
any of the following type of sheets:
•
Documents of coated paper
•
Documents that are almost completely covered with
printed text or graphics
•
Chemically treated documents such as carbonless paper
•
Documents containing a large amount of calcium
carbonate
•
Documents written by pencil
•
Documents on which the toner is not fused sufficiently.
For details on cleaning the ADF, refer to section 4.3 "Clean-
ing the ADF" of "fi-6140/fi-6240 Operator's Guide" on the
Setup CD-ROM.
Standard Cleaning Cycle
Clean these parts after every 5,000
sheets.