Fujitsu fi-5530C - Document Scanner Getting Started - Page 23

Browse online or download pdf Getting Started for Scanner Fujitsu fi-5530C - Document Scanner. Fujitsu fi-5530C - Document Scanner 28 pages. Color departmental scanner
Also for Fujitsu fi-5530C - Document Scanner: Getting Started (28 pages), Installation Procedures Manual (7 pages), Installation Procedures Manual (9 pages), Installation Procedures (3 pages), Brochure & Specs (2 pages), Specifications (2 pages), Consumable Replacement And Cleaning Instructions (14 pages), Cleaning Instructions Manual (13 pages), Instruction Manual (10 pages)

Fujitsu fi-5530C - Document Scanner Getting Started
Symptom
Paper is not fed (pick error
occurs frequently, or docu-
ment stops midway).
The generated images are
elongated.
There is a shadow on the
leading edge of the gener-
ated image?
Check this item
Do the documents satisfy the "Docu-
ment Quality" and the "Multi feed
Detection Conditions" in the chapter 6
of "fi-5530C2 Operator's Guide"?
Is the Pick roller dirty?
Is the Pick roller worn out?
Is there any debris on the document feed
path?
Are the Feed rollers dirty?
Have you adjusted the scan scale?
Are the Feed rollers dirty?
Have you adjusted the offset (the scan-
ning starting position)?
fi-5530C Image Scanner Getting Started
Remedy
Use the documents that satisfy the "Document
Quality" and the "Multi feed Detection Condi-
tions" in the chapter 6 of "fi-5530C2 Operator's
Guide."
Clean the Pick roller. For details, refer to section
3.2 "Cleaning the ADF"of "fi-5530C2 Operator's
Guide."
Clean the Pick roller. For details, refer to section
4.3 "Replacing the Pick Roller" of "fi-5530C2
Operator's Guide."
Remove any debris from the document feed path.
Clean the Feed rollers. For details, refer to section
3.2 "Cleaning the ADF"of "fi-5530C2 Operator's
Guide."
Select "Scanners and Cameras" in the control
panel, then click the [Device Set] tab to adjust
scale.
Clean the Feed rollers. For details, refer to section
3.2 "Cleaning the ADF"of "fi-5530C2 Operator's
Guide."
Adjust the [Sub-scan Setting] on [Scanners and
Cameras] in the control panel.
AP-2