Also for Fujitsu ETERNUS DX Disk: User Manual (35 pages), User Manual (42 pages), Configuration Manual (28 pages), Configuration Manual (44 pages), Configuration Manual (28 pages), Configuration Manual (29 pages), Configuration Manual (25 pages), Configuration Manual (32 pages), Configuration Manual (31 pages), Configuration Manual (43 pages), Configuration Manual (21 pages), Configuration Manual (24 pages)

Fujitsu ETERNUS DX Disk Configuration Manual
Chapter 2
Setup Procedure for QLogic Converged Network Adapter Cards
2.2
Setting Up the Converged Network Adapter Cards
7
Perform the BIOS settings for the Converged Network Adapter card.
Check the parameter values in the [Adapter Settings] window against those in the following table. For
details on how to set the values, refer to the BIOS Readme file and Converged Network Adapter card
user's guide.
Parameter
BIOS Address
BIOS Revision (*1)
Adapter Mac Address
Interrupt Level
Adapter Port Name
Host Adapter BIOS
Frame Size
Loop Reset Delay
Spinup Delay
Fibre Channel Tape Support
*1: The BIOS version of the Converged Network Adapter card is displayed. Check that the BIOS version
is the same as shown in "Server Support Matrix".
8
Return to the [Configuration Settings] menu by pressing the [Esc] key.
9
Select [Advanced Adapter Settings] from the [Configuration Settings] menu and press the [Enter] key.
Check the parameter values in the [Advanced Adapter Settings] window against those in the following
table.
Parameter
Execution Throttle
LUNs per Target
Enable Target Reset
Login Retry Count
Port Down Retry Count
Link Down Timeout
Operation Mode
Interrupt Delay Timer
Enable Interrupt
EV Controller Order
LR Enable
Primary FCF VLAN ID
10
Press the [Esc] key twice to return to the [Fast!UTIL Options] menu.
If the BIOS settings were changed, save the settings using [Save xxxxxx]. When two or more Converged
Network Adapter cards are installed in the server, select the second or later Converged Network Adapter
card using the following steps, and set the BIOS of the selected card.
(1)
Select [Select Host Adapter] from the [Fast!UTIL Options] menu and press the [Enter] key.
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware
Adapter Settings
Fixed for each card
Enabled or Disabled
2048
5
Disabled
Disabled
Setting value
65535
8
Yes
8
30
30
0
0
NO
Disabled
Disabled
Disabled
25
Copyright 2015 FUJITSU LIMITED
Remarks
Settings cannot be changed.
Set [Enabled] for SAN Boot.
Set [Disabled] for non SAN Boot.
If the current parameter values are dif-
ferent, change them to the indicated
values.
Remarks
If the current parameter values are dif-
ferent, change them to the indicated
values.
®
ESX
P3AM-4772-11ENZ0