Fujitsu ETERNUS DX60 S3 Configuration Manual - Page 23
Browse online or download pdf Configuration Manual for Storage Fujitsu ETERNUS DX60 S3. Fujitsu ETERNUS DX60 S3 28 pages. Hybrid storage systems, all-flash arrays, power synchronized unit
Also for Fujitsu ETERNUS DX60 S3: Configuration Manual Server Connection (12 pages), Configuration Manual (13 pages), Site Planning Manual (41 pages), Safety Precautions (12 pages)
Chapter 7
Checking Connections
7.2
Setting Up the Server to Recognize the Logical Units
Check that all connected devices are listed in the ioscan output and "CLAIMED" is displayed in "S/W
State".
The following example shows the output of ioscan (LegacyView) when ETERNUS DX storage systems are
connected to a server.
# ioscan
H/W Path
============================================================
:
255/0
255/0/0.0
255/0/0.0.0
255/0/0.0.0.0
255/0/0.0.0.1
255/0/0.0.0.2
255/0/0.0.0.3
255/0/0.0.0.4
:
#
When the ETERNUS DX storage systems are connected for the first time, the device file (for exam-
ple, /dev/dsk/c4t0d0) sometimes may not be created.
If this happens, use the "insf" command to create the device file. Specify the hardware path name as
follows, and execute.
# insf -H hw_path_to_device -e
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (iSCSI) for HP-UX
Class
iscsi
ext_bus
target
disk
disk
disk
disk
disk
23
Copyright 2014 FUJITSU LIMITED
Description
iSCSI Virtual Node
iSCSI-SCSI Protocol Interface
FUJITSU ETERNUS_DXL
FUJITSU ETERNUS_DXL
FUJITSU ETERNUS_DXL
FUJITSU ETERNUS_DXL
FUJITSU ETERNUS_DXL
P3AM-3402-14ENZ0