Fujitsu ETERNUS DX8100 S2 Configuration Manual - Page 22

Browse online or download pdf Configuration Manual for Storage Fujitsu ETERNUS DX8100 S2. Fujitsu ETERNUS DX8100 S2 28 pages. Disk storage system settings
Also for Fujitsu ETERNUS DX8100 S2: User Manual (35 pages), User Manual (42 pages), Configuration Manual (15 pages)

Fujitsu ETERNUS DX8100 S2 Configuration Manual
Chapter 7
Checking Connections
7.1

Turning on the Devices

To turn on the connected devices, use the following procedure:
1
Turn on any devices (such as LAN switches) on the LAN path between the ETERNUS DX and server.
2
After checking that the Ready (or equivalent) LED of the LAN switch is lit, turn on the ETERNUS DX
storage systems.
3
After checking that the ETERNUS DX's Ready LED is lit, turn on the server.
7.2

Setting Up the Server to Recognize the Logical Units

Make the server recognize the logical units (LUN) set in the ETERNUS DX storage systems.
1
Use the "ioscan" command to check which devices are connected.
Enter as follows for LegacyView (old format) results:
# ioscan -fn
Enter as follows for AgileView (HP-UX11iv3 and newer format) results:
# ioscan -fnN
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (iSCSI) for HP-UX
22
Copyright 2014 FUJITSU LIMITED
P3AM-3402-14ENZ0