Fujitsu ETERNUS DX8700 S2 User Manual - Page 15

Browse online or download pdf User Manual for Storage Fujitsu ETERNUS DX8700 S2. Fujitsu ETERNUS DX8700 S2 42 pages. Disk storage system settings
Also for Fujitsu ETERNUS DX8700 S2: User Manual (35 pages), Configuration Manual (28 pages), Configuration Manual (15 pages)

Fujitsu ETERNUS DX8700 S2 User Manual
Chapter 3
Notes
3.6
LAN Environment Notes
Example of a LAN switch connection configuration
Business server A
Card#2
10
ETERNUS DX Disk storage system
A separate LAN segment is used for each
Server/Storage grouping (*2).
Here, LAN ports 1, 2 and 10 comprise VLAN1,
while LAN ports 3 and 11 comprise VLAN2.
*1: In this system configuration, multipaths provide redundant connections between the servers and stor-
age system. LAN switches #1 and #2 provide physical separation of the network paths.
*2: A separate LAN segment is provided in the LAN switch (using the switch VLAN function) for each group-
ing of business servers and storage systems (equivalent to the FC zones).
ETERNUS DX Disk storage systems User's Guide -Server Connection-(iSCSI) for VMware
LAN switch
[Business LAN]
LAN
Card#1
Card#1
Business server B
LAN
LAN
LAN
Card#3
Card#2
1
2
3
LAN switch #1
LAN switches should not
[iSCSI LAN]
be inter-connected (*1)
11
12
LUN1
LUN2
LUN3
Copyright 2013 FUJITSU LIMITED
LAN
LAN
Card#1
Business server C
LAN
LAN
LAN
Card#3
Card#2
Card#3
1
2
3
LAN switch #2
[iSCSI LAN]
10
11
Management
LAN switch
LAN port
[Management LAN]
The iSCSI LAN and management LAN
segments are kept separate in the iSCSI
LAN switches, helping maintain the security
of each.
15
Business LAN
Similarly to FC-SAN,
a dedicated LAN is used for iSCSI,
not the business LAN.
iSCSI LAN
12
Management LAN
®
ESX
P3AM-3412-13ENZ0