Fujitsu ETERNUS4000 500 Connection Manual - Page 13
Browse online or download pdf Connection Manual for Storage Fujitsu ETERNUS4000 500. Fujitsu ETERNUS4000 500 19 pages. Disk storage systems (fibre channel) for oracle solaris
Also for Fujitsu ETERNUS4000 500: Manual (28 pages), Manual (21 pages), Server Connection Manual (25 pages), Server Connection Manual (32 pages)
Chapter 3 Setting Up the Server
>
3.2 Setting Up Brocade Fibre Channel Cards
The following procedure shows an example for setting the port speed, topology, and frame data
size.
Procedure
1
2
3
4
5
6
P3AM-4562-01ENZ0
ETERNUS Disk storage systems Server Connection Guide for Oracle Solaris
Check the "port_id" of the target port.
# bcu port --list
Port#
Type
PWWN/MAC
1/0
fc
10:00:00:05:1e:e7:45:7b
1/1
fc
10:00:00:05:1e:e7:45:7c
Check the port ID
The port ID checked here is used to set the port speed, topology, and frame data size.
Set the port speed to "8G".
# bcu port --speed 1/0 8
Setting will be enforced after port --disable and -enable
Set the topology to "p2p".
# bcu port --topology 1/0 p2p
Setting will be enforced after port --disable and --enable
Set the frame data size to "2048".
# bcu port --dfsize 1/0 2048
Setting will be enforced after port --disable and -enable
Execute the "port disable|enable" command to apply the port speed, topology,
and frame data size settings.
# bcu port --disable 1/0
port disabled
# bcu port --enable 1/0
port enabled
Check the port speed, topology, and frame data size that have been set.
•
Port speed confirmation
# bcu port --speed 1/0
Current port speed is:
Configured port speed is:
•
Topology confirmation
# bcu port --topology 1/0
Current topology is:
Configured topology is:
FC Addr/ Media
Eth dev
010400
sw
010500
sw
8G
8G
P2P
P2P
13
State
Spd
Linkup
8G
Linkup
8G
Copyright 2010 FUJITSU LIMITED