Indesit IWME 147 Instructions For Use Manual - Page 3

Browse online or download pdf Instructions For Use Manual for Washer Indesit IWME 147. Indesit IWME 147 20 pages.
Also for Indesit IWME 147: Instructions For Use Manual (20 pages)

Indesit IWME 147 Instructions For Use Manual

Connecting the drain hose

Where it connects to
the waste water pipe
cut end off spigot or
remove the blanking cap
! We advise against the use of hose extensions;
in case of absolute need, the extension must
have the same diameter as the original hose
and must not exceed 150 cm in length.
Ensure that if the drain hose is pushed into a
standpipe, that the end does not go down more
than 15cms (6 inches). If the hose is pushed
down too far, this may cause the machine to
self -syphon ie. continuously empty as it is filling.
Electric connection
Before plugging the appliance into the mains
socket, make sure that:
• the socket is earthed and in compliance with
the applicable law;
• the socket is able to sustain the appliance's
maximum power load indicated in the Tech-
nical details table (see page 5);
Connect the drain
hose, without ben-
ding it, to a draining
duct or a wall drain
situated between 65
and 100 cm from the
floor;
The drain hose may
be connected to
an under-sink trap.
Before connecting
the drain hose from
the machine ensure
that any blanks or
removable ends have
been taken off the
spigot.
If it is place over
the edge of a basin
or sink be sure the
free end of the hose
should not be under-
water.
• the supply voltage is included within the va-
lues indicated on the Technical details table
(see page 5);
• the socket is compatible with the washing
machine's plug. If this is not the case, repla-
ce the socket or the plug.
Your appliance is now supplied with a 13 amp
fused plug it can be plugged into a 13 amp
socket for immediate use. Before using the
appliance please read the instructions below.
WARNING - THIS APPLIANCE MUST BE EAR-
THED. THE FOLLOWING OPERATIONS SHOULD
BE CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Replacing the fuse:
When replacing a faulty fuse, a 13 amp ASTA
approved fuse to BS 1362 should always be
used, and the fuse cover re-fitted. If the fuse
cover is lost, the plug must not be used until a
replacement is obtained.
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of
the correct colour as indicated by the coloured
marking or the colour that is embossed in words
on the base of the plug. Replacements can be
obtained directly from your nearest Service Depot.
Removing the plug:
If your appliance has a non-rewireable moulded
plug and you should wish to re-route the mains
cable through partitions, units etc., please en-
sure that either:
the plug is replaced by a fused 13 ampere
re-wearable plug bearing the BSI mark of
approval.
or:
the mains cable is wired directly into a 13
amp cable outlet, controlled by a switch, (in
compliance with BS 5733) which is accessible
without moving the appliance.
Disposing of the plug:
Ensure that before disposing of the plug itself,
you make the pins unusable so that it cannot
be accidentally inserted into a socket.
Instructions for connecting cable to an alternative
plug:
Important: the wires in the mains lead are co-
loured in accordance with the following code:
Green & Yellow
Earth
Blue
Neutral
Brown
Live
GB
3