Indesit ICD 661 UK Service Information - Page 24

Browse online or download pdf Service Information for Dishwasher Indesit ICD 661 UK. Indesit ICD 661 UK 28 pages. Table top

Indesit ICD 661 UK Service Information
Indesit
Company
L.
CIRCULATING PUMP ASSEMBLY
1.
Remove the tank (K).
2.
Release the runner mounting support (rear of
motor).
3.
Noting the orientation, disconnected the
wiring and earth to the motor.
4.
Remove the 3 motor fixing bolts into the sump.
5.
Lift the motor clear.
M. CIRCULATING MOTOR CAPACITOR
1.
Remove the tank (K).
2.
Noting the wiring orientation, disconnect the
wiring.
3.
Lift the capacitor clear.
N. DRAIN PUMP
1.
Remove the tank (K).
2.
Remove the 2 fixing screws (one at the top
and the bottom).
3.
Twist anticlockwise to remove.
Service Manual UK
Circulating Pump Fixing Screws
24 of 28