Electrical connections
! Ovens equipped with a three-pole power supply
cable are designed to operate with alternating current
at the voltage and frequency indicated on the data
plate located on the appliance (see below).
Fitting the power supply cable
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load
indicated on the data plate (see side).
The appliance must be directly connected to the
mains using an omnipolar circuit-breaker with a
minimum contact opening of 3 mm installed between
the appliance and the mains, suitable for the load
indicated and complying with current electrical
regulations (the earthing wire must not be interrupted
by the circuit-breaker). The supply cable must not
come into contact with surfaces with temperatures
higher than 50°C.
! The installer must ensure that the correct electrical
connection has been made and that it is compliant
with safety regulations.
Before connecting to the power supply, make sure
that:
• The appliance is earthed and the plug is
compliant with the law.
• The socket can withstand the maximum power of
the appliance, which is indicated on the data
1. Open the terminal
board by inserting a
screwdriver into the
side tabs of the cover.
Use the screwdriver as
a lever by pushing it
down to open the cover
(see diagram).
2. Loosen the cable
clamp screw and
remove it, using a
screwdriver as a lever
(see figure).
3. Remove the wire
contact screws L-N-
, then fasten the wires
under the screw heads,
respecting the colour
code: Blue (N), Brown
(L) and Yellow-Green
Verde (
).
plate (see below).
• The voltage must be in the range between the
values indicated on the data plate (see below).
• The socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it. Do
not use extension cords or multiple sockets.
! Once the appliance has been installed, the power
supply cable and the electrical socket must be easily
accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced
by authorised technicians only (see Assistance).
! The manufacturer declines any liability should
these safety measures not be observed.

DATA PLATE

width cm 43.5
Dimensions
height cm 32
depth cm 40
Volume
lt. 56
voltage: 220-240V ~ 50/60 Hz
Electrical
(see data plate)
connections
maximum power absorbed 2250W
Directive 2002/40/EC on the label
of electric ovens.
Standard EN 50304
Models with cooling ventilation:
Energy consumption for Natural
convection heating mode:
Convection
Declared energy consumption for
Forced convection Class heating
ENERGY LABEL
mode:
Models
ventilation:
Energy consumption for Forced
convection heating mode:
Multi-cooking
Declared energy consumption for
Natural convection Class heating
mode:
This appliance conforms to the
following European Economic
Community directives:
2006/95/EEC of 12/12/06 (Low
Voltage) and subsequent
amendments;
-2004/108/EEC of 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments;
93/68/EEC of 22/07/93 and
subsequent amendments.
2002/96/EC and subsequent
amendments.
GB
Multi-cooking
without
cooling
Convection
3