a) replace the hose holder mounted on the
EN
EN
appliance with that supplied in the bag of "cooker
accessories".
b) Replacing the burner nozzles on the hob:
• remove the grids and slide the burners from their
housings;
• unscrew the nozzles using a 7 mm socket
spanner, and replace them with nozzles for the
new type of gas (see table 1 "Burner and nozzle
characteristics").
• replace all the components by repeating the steps in
reverse order.
c) Minimum regulation of the hob burners:
• turn the tap to minimum;
• remove the knob and adjust the regulation screw,
which is positioned in or next to the tap pin, until the
flame is small but steady.
In the case of liquid gas, the regulation screw must
be screwed in to the bottom.
If the appliance is connected to a liquid gas supply, the
bypass screw must be set to a minimum.
3. While the burner is alight, quickly change the position of the
knob from minimum to maximum and vice versa several times,
checking that the flame is not extinguished.
Upon completion of adjustment, reseal using sealing
wax or an equivalent material.
Adapting to different types of gas
• pull out the sliding oven bottom
V
•
unscrew the two screws and take off the shield
protecting the burner (in main oven burner only).
12
• check that the flame does not
turn off when you turn the tap
quickly from high to low.
d)
Regulating the
primary air of the burners:
The primary air of the burners
requires no regulation.
In order to adapt the oven to
a different type of gas with
respect to the gas for which it
was manufactured (indicated
on the label), follow these
simple steps:
a) Replacing the oven burner
nozzle
• open the oven door fully
V
! This procedure must be performed by a qualified
technician who has been authorised by the
manufacturer.
• Pry the fixing tab "V" and remove the oven burner
• Unscrew the oven burner nozzle using the socket
spanner for the nozzles "Z", or a 7 mm socket
spanner, and replace it with a nozzle suited to the
new type of gas (see Table 1).
Take particular care handling the spark plug wires
and the thermocouple pipes.
• Replace all the parts, following the steps described
above in the reverse order.
b) Minimum regulation of the gas oven burner with
thermostat:
• light the burner as described in the paragraph "the
oven knob" of the instruction booklet.
• turn the knob to Max for about 10 minutes and then
turn the knob to the Min setting;
• remove the knob;
• regulate the screw positioned outside the thermostat
pin until the flame is small but steady.
In the case of liquid gas, the regulation screw must
be screwed in to the bottom.
check that the burner does not turn off when you
turn the knob from Max to Min and and when you
open and close the oven door quickly.
Adapting the gas grill to different types of gas
Replacing the nozzle of the grill burner:
• remove the screw and then slide out the grill burner
"V" (see Figure);
• unscrew the grill burner nozzle using the special
socket spanner for the nozzles (see Figure) or better
still a 7mm socket spanner; replace the nozzle with
V
Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used.
This sticker is available from our Service Centres.
Z
Note
Should the pressure of the gas used be different (or
vary) from the recommended pressure, it is necessary
to fit a suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative
to "regulators for channelled gas".
a nozzle
for the
new type
of gas
(see table
1).
I