Indesit IT50L Operating Instructions Manual - Page 7
Browse online or download pdf Operating Instructions Manual for Cookers Indesit IT50L. Indesit IT50L 24 pages. Indesit it50g s; it50g1 s; it50l s; it50g1; it50l; it50g; itl50g1; itl50gm; itl50ga; itl50gw 50cm free standing gas cooker
Also for Indesit IT50L: Operating Instructions Manual (24 pages)
• turn the knob to Max for about 10 minutes and then
turn the knob to the Min setting;
• remove the knob;
• regulate the screw positioned outside the thermostat
pin until the flame is small but steady.
! in the case of liquid gas, the regulation screw must
be screwed in to the bottom.
check that the burner does not turn off when you
turn the knob from Max to Min and and when you
open and close the oven door quickly.
Adapting the gas grill to different types of gas
Replacing the nozzle of the grill burner:
• remove the screw and then slide out the grill burner
"V" (see Figure);
• unscrew the grill burner nozzle using the special
socket spanner for the nozzles (see Figure) or better
still a 7mm socket spanner; replace the nozzle with
V
Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used.
This sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or
vary) from the recommended pressure, it is necessary
to fit a suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative
to "regulators for channelled gas".
•
a nozzle
for the
new type
of gas
(see table
1).
I
GB
7