Indesit K 3G21/G Instructions For Installation And Use Manual - Page 7

Browse online or download pdf Instructions For Installation And Use Manual for Cookers Indesit K 3G21/G. Indesit K 3G21/G 17 pages. Indesit cookers operating instructions
Also for Indesit K 3G21/G: Instructions For Installation And Use Manual (17 pages), Operating Instructions Manual (12 pages), Operating Instructions Manual (12 pages)

Indesit K 3G21/G Instructions For Installation And Use Manual
Pay particular attention to the plug wires and
thermocouple tubes.
Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
51
(Small)(A)
Oven
-
Grill
-
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
Burner and nozzle characteristics
Thermal Power
kW (p.c.s.*)
Nominal
Reduced
3.00
0.7
1.90
0.4
1.00
0.4
3.10
1.0
2.50
-
Nominal (mbar)
3
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in compliance
with current National Regulations relative to "regulators
for channelled gas".
Liquid Gas
By-Pass
Nozzle
1/100
1/100
(mm)
(mm)
41
87
30
70
30
52
46
85
-
80
S S
A
R
K3G2/G
K3G21/G
K3G21S/IR
7
Natural Gas
Flow*
Nozzle
g/h
1/100
***
**
(mm)
218
214
128
138
136
104
73
71
76
225
221
132
182
179
122
28-30
37
20
25
35
45
Flow*
l/h
286
181
95
295
227
20
17
25