The following instructions are for your installer who should
follow them to ensure that your appliance is properly installed,
regulated and serviced in compliance with current directives.
Important: unplug the appliance from the mains before
carrying out any maintenance or regulations.
Installation of the cooker
The cooker is prepared with protection degree against
excessive heating of type X, the appliance can therefore be
installed next to cabinets, provided the height does not
exceed that of the hob. If the cooker is placed touching walls
or sides of neighbouring cabinets, these must be capable of
withstanding a temperature rise of 60°C above room tempe-
rature.
Levelling
The cooker is supplied with adjustable feet to ensure perfect
levelling. They can be screwed in the seats positioned in the
corners of the cooker base.
Assembling the legs (Fig. A)
Four legs are included to make the cooker 5 cm higher. The
legs are assembled under the base of the cooker. To
assemble, proceed as follows:
Front part tilt the cooker towards the back; unscrew feet
"A" if already installed. Insert the threaded pin of leg "B"
in the appropriate threaded holes "C", turn clockwise all
the way and the level the cooker by turning the foot of leg
"D" clockwise or counter-clockwise.
Rear part follow the same procedure.
Assembling the base panel (Fig. B)
A base panel is provided for covering the legs. To assemble
proceed as follows:
after assembling the legs, unscrew the 2 screws "E" and
use them to fasten base panel "F".
N.B.: Never install the base panel before fastening the legs.
E
B
D
C
Fig. A
For a correct installation of the cooker the following
precautions must be followed:
a) The cooker may be located in a kitchen, a kitonen/diner
or bed sitting room, but not in a bathroom or shower room.
b) The furniture units next to the cooker, that is higher than
the working boards, must be placed at least 110mm from

Installation instructions

A
F
E
Fig. B
the edge of the board. Curtains must not be fitted
immediately behind the cooker or within 110 mm. of the
sides of the cooker.
c) The hoods must be installed according to the
requirements in the hood handbook.
d) Wall cabinets may be fitted
in line with the sides of the
base units, providing that
the lower edge of the wall
cabinets is a minimum of
420 mm above the worktop.
The minimum distance
combustible
material
kitchen units can be fitted
directly above the worktop
is 700mm.
e) The wall in contact with the back of the cooker must be of
flameproof material.
Electrical connection
Electric cookers come without a power supply cable. The
cooker is designed to operate on an electricity supply which
conforms to the electrical data shown on the Rating Plate.
The cooker can be connected to the mains only after
removing the back panel of the cooker itself with a
screwdriver.
N.B.: the following installation procedure must be carried
out by a qualified electrician. The electrical installation must
comply with the IEE Regulations, Building & local By-Lays.
For the installation of the feeding cable carry out the following
operations:
unscrew the screws of the cable stop and the three screws
of the contacts L-N-
fix the wires in the main cable.
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Blue
Brown
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Green & Yellow wire to terminal marked "E" or
coloured Green or Green & Yellow.
Brown wire to terminal marked "L" or coloured Red.
Blue wire to terminal marked "N" or coloured Black.
L
Brown
N
Bleu
Cable H05RRF - 3 x 2,5 mm
fix the feeding cable in the special cable stop and close
the rear cover of the cooker.
N.B.: the power supply cable must have these minimum
requirements:
Type:
H05RR-F
Section: 3x4 mm
2
3
HOOD
500
Min.
mm.
.
Earth
Neutral
Live
230-240 V ~
E
Yellow - Green
2
or