ELECTRICAL CONNECTION

The electrical connection for the hob and for any built -in oven must be carried out separately, both for
safety purposes and to make extracting the oven easier.
Single-Phase Connection
The hob is equipped with a pre-connected electricity supply cable, which is designed for single-phase
connection.
Connect the wires in accordance with the instructions given in the following table and diagrams:
Voltage and
mains frequency
220-240V 1+N ~
50/60 Hz
Other Types of Connection
Voltage and
mains frequency
400V - 2+N ~
50/60 Hz
220-240V 3 ~
50/60 Hz
If the mains supply corresponds with one of the following:
Voltage and mains frequency
400V - 2+N ~ 50/60 Hz
220-240V 3 ~ 50/60 Hz
Separate the wires and connect them in accordance with the instructions given in the following table
and diagrams.
Connecting the Electricity Supply Cable to the Mains
If the appliance is being connected directly to the electricity mains an omnipolar switch must be
installed with a minimum opening of 3 mm between contacts.
The installer must ensure that the correct electrical connection has been made and that it is fully
compliant with safety regulations.
Service Manual UK
Electrical cable
Wire connection
: yellow/green
N
: the two blue wires together
L
: brown and black together
Electrical cable
N: the two blue wires
L1: black
L2: brown
14 of 33
Wire connection
: yellow/green;
together