AEG 222 D Installation And Operating Instructions Manual - Page 8
Browse online or download pdf Installation And Operating Instructions Manual for Ventilation Hood AEG 222 D. AEG 222 D 20 pages. Fume extractor hood
Also for AEG 222 D: Installation And Operating Instructions Manual (20 pages), Installation And Operating Instructions Manual (20 pages), Installation And Operating Instructions Manual (20 pages), Installation And Operating Instructions Manual (20 pages)
Installation
Safety warnings for kitchen unit installer
• When used as an extractor unit, the hood must be fitted with a
120mm diameter hose.
• If the fumes must be forced out through the wall, you must
obtain a MKZ sizable wall exhaust pipe (with external exhaust and
air intake), E-Nr.-610 899 004 (0 120 mm) which is one of our
optional parts.
• When installing the hood, make sure you respect the fol¬
lowing minimum distance from the top edge of the cooking
hob/ring surfaces:
electric cookers
650 mm
gas cookers
700 mm
• The hood cannot be connected to flues of other appliances that
run on energy sources other than electricity.
• The air outlet must not be connected to chimney flues or com¬
bustion gas ducts. The air outlet must under no circumstances be
connected to ventilation ducts for rooms in which fuel-burning
appliances are installed.
• It is advisable to apply for authorization from the relevant
controlling authority when connecting the outlet to an unused
chimney flue or combustion gas duct.
The air outlet installation must comply with the regulations laid
down by the relevant authorities.
• When the unit is used in its extractor version, a sufficiently large
ventilation hole must be provided, with dimensions that are
approximately the same as the outlet hole.
• National and regional building regulations impose a number of
restrictions on using hoods and fuel-burning appliances connected
to a chimney, such as coal or oil room-heaters and gas fires, in
the same room.