Electrical connection
Safety warnings for the electrician
Before connecting the appliance to the power supply, check that the
voltage indicated on the rating plate corresponds to the mains power
supply available. Appliances fitted with a plug can be connected to
any standard power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must
only be installed by an electrician authorised by the local electricity
board. When installing, an omnipolar disconnector with a distance of
at least 3 mm between contacts must be provided.
Fixed connection of the appliance must only be carried out by an
authorised electrician.
Installation - Fig. 8
Only 5708 D: this model is equipped with two outlet hole. 2 hoses are
therefore necessary for discharging the fumes.
If present, an opening for the easy passage of both hoses must be
made in the top of the wall-unit.
• Drill the base of the wall unit to allow for passage of the hood body.
Fig. 7.
• Drill the top of the wall unit to allow for passage of the exhaust pipe
and the electrical cable. Fig. 7.
• Remove the grease filter (1).
• Remove the grease filter support frame, by pressing the two spring
clamps located at the sides of the frame (2).
• Through the top of the wall unit, insert a pipe with a diameter of
120mm at the connection ring (3).
• Fit the connection ring on the hood exhaust outlet (4) and fasten it
to the exhaust pipe.
• Insert the body of the hood into the hole in the base of the wall unit
(5) – check the position of the exhaust pipe and the electrical cable,
press firmly so that the anchor springs (6) engage above the bottom
of wall unit. Tighten the screws in the anchor springs firmly.
• If necessary the hood can be fastened with four more screws (7).
• Replace the grease filter support frame.
• Replace the grease filter.