AEG 8359 D Installation And Operating Instructions Manual - Page 10
Browse online or download pdf Installation And Operating Instructions Manual for Ventilation Hood AEG 8359 D. AEG 8359 D 18 pages. Fume extractor hood
Installation - Fig. 3
Put the template onto the wall (1) and drill two Ø12mm holes (2).
Fit two hooks (3) on the drilled holes.
Hang the hood on the hooks and adjust the position of the hood
using the two screws on the bottom of the hooks (5).
Remove the metal filters (4) and mark two points (6). Remove the
hood and drill two Ø8mm holes on the marked points.
Fit two Ø8mm wall dowels (7), Hang again the hood and fix the
hood definitively with two screws 5X45 (8).
Fix the chimney support (10) with two screws 5 x 45 mm (9) and
two wall dowels (11) on the wall close to the ceiling.
For exhausting version: Fit the connection ring (S) on the top of
the hood with two screws Ø 3,5 x 6,5 mm (12S) then fit an
exhausting pipe long enough to reach the outside (13S).
For recycling version: Fix definitively the deflector (13K)
on the top of the hood with two screws Ø 3,5 x 6,5 mm
(12K).
Prepare the electric connection (14) (see relative chapter).
Fit the chimney (15) and fix it on the chimney support with two
screws 3,0 x 9 mm (16).
The lower part of the chimney must be slided down and inserted
on the housing on the upper part of the hood (18).
Fit the two grids (17) on both sides of the chimney.
26