AEG protect d. 3000 Operating And Installation Manual - Page 13

Browse online or download pdf Operating And Installation Manual for Ventilation Hood AEG protect d. 3000. AEG protect d. 3000 19 pages. Aeg cooktop user manual
Also for AEG protect d. 3000: Operating And Installation Instructions (17 pages)

AEG protect d. 3000 Operating And Installation Manual

Technic Details

Dimensions - extractor version (in cm):
Height x Width x Depht
Dimensions - filter version (in cm):
Height x Width x Depht
Maximum absorbed power:
Motor absorption:
Lighting:
Lenght of the cable:

Mounting accessories included

1 deflector (3 pieces to assemble)
2 metal screws 3,5 x 13 (to assemble the deflector)
1 chimney support (3 pieces to assemble)
4 metal screws 4 x 8 (to assemble the chimney support)
4 metal screws 3,5 x 9,5 (to affix the deflector to the support)
1 reduction flange Ø 125-120 mm
1 support bracket
5 wood-screws 5 x 45 mm (for wall mounting)
5 wall plugs Ø 8 mm (for wall mounting)
4 metal screws 2,9 x 6,5 (for chimney flue mounting)
4 metal screws 4 x 35 (to affix the screen to the cooker hood)
2 metal screws 3 x 9 (to affix the frame to the cooker hood)
1 allen spanner (for TORX screws)

Electrical connection

Safety warnings for the electrician

Before connecting the appliance to the power supply, check that the volt-
age indicated on the rating plate corresponds to the mains power supply
available. Appliances fitted with a plug can be connected to any standard
power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must only
be installed by an electrician authorised by the local electricity board.
When installing, an omnipolar disconnector with a distance of at least
3mm between contacts must be provided.
The manufacture declines all responsibility for malfunctions resulting from
failure to comply with the above instructions.
Electrical connection
220-240 V – by means of fixed power cable with plug.
(Fixed connection of the appliance must only be carried out by an author-
ised electrician.)
74
66-112 x 89,8 x 50
75,5-122 x 89,8 x 50
210 W
1 x 170 W
2 x 20W
150 cm