Kohler K-13672 Installation Manual - Page 10
Browse online or download pdf Installation Manual for Bathroom Fixtures Kohler K-13672. Kohler K-13672 33 pages.
Red LED
Faucet Lead
Connection
Green LED
Circuit
Board
8. Troubleshooting
The faucet works properly if the following conditions occur during
the first 10 minutes after power up:
NOTE: To see the sensors you must remove the cover of the control
box.
The GREEN LED is on constantly and the faucet is running when
the faucet sensor sees an object.
If the faucet senses an object for more than 30 seconds, the faucet
stops flushing and the GREEN LED flashes until the object has
been removed.
If the faucet does not turn on:
Check the batteries for a charge and proper installation. Replace if
necessary.
Make sure the battery pack lead wires and the faucet are plugged
into the circuit board.
Check that the supply lines are open.
1031173-2-B
Straight Connector
10
Electrical
Tubing
Kohler Co.