Kohler Taboret Rite-Temp K-T8228-4A Installation Manual - Page 8
Browse online or download pdf Installation Manual for Bathroom Fixtures Kohler Taboret Rite-Temp K-T8228-4A. Kohler Taboret Rite-Temp K-T8228-4A 25 pages. Single-control bath and shower trim
Install the Faceplate and Handle (cont.)
Rotate the valve stem fully counterclockwise.
Position the handle stem over the valve stem with the eyelets
vertical. Secure with a screw.
Position the stem extension on the valve stem.
Confirm that the O-ring is in place and position the skirt on the
stem extension. Secure with a setscrew.
Slide the faceplate over the skirt. Secure it with two screws.
Install the bonnet and adapter onto the skirt. Secure with a screw.
Attach the handle to the adapter.
5. Complete the Installation
Turn the valve fully counterclockwise to the off position.
Remove the aerator assembly from the spout by turning it
counterclockwise.
Turn on the main water supply.
Turn the valve to the center and run water for approximately one
minute to flush the system.
Check all connections for leaks.
Reinstall the aerator.
1031365-2-B
8
Kohler Co.