Kohler Hourglass 30 K-1201 Installation Instructions Manual - Page 5

Browse online or download pdf Installation Instructions Manual for Bathtubs Kohler Hourglass 30 K-1201. Kohler Hourglass 30 K-1201 20 pages.

Kohler Hourglass 30 K-1201 Installation Instructions Manual
2. ROUGHING-IN: K-1206, K-1206-L, K-1206-R, HOURGLASS 32
A. ORDERING INFORMATION
Applicable product:
Drop-in rim style
Left outlet, integral flange
Right outlet, integral flange
Accessories/hardware:
Jet trim kit
Apron
Drain
Vinyl tiling-in bead*
*Use K-1177 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated branch circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
120 V, 15 A, 60 Hz
16"
1-3/8"
8-3/8"
60"
2-3/4"
2-7/8"
3"
Kohler Co., Kohler WI
K-1206
shown
K-1206-L
not shown
K-1206-R
not shown
K-9694
included
K-1278
optional
K-7161-AF recommended
K-1177
optional
20"
18-1/2"
3/8"
C. PRODUCT INFORMATION
Fixture*:
basin area
Bathing well
44" x 22"
water depth
To overflow
15-1/8"
* Approximate measurements for comparison only.
Pump:
HP
1-speed
3/4
D. INSTALLATION NOTES
Read the entire installation instruction before beginning the
installation.
Pump is supplied with a grounding-type plug-in cord. Locate
the outlet behind the whirlpool, and within 24" of the pump.
The optional apron must be installed before the finish floor
and wall materials are installed.
ROUGHING-IN NOTES
Fixture conforms to ANSI Standard Z124.1. All
dimensions are nominal.
No change in measurements if connected with drain il-
lustrated.
Cut-out
K-1206 drop-in rim style, 58-1/2" x
30-1/2"
Minimum access panel:
Pump/control 20" W x 15" H
PUMP/CONTROL ACCESS
32"
1-1/2" O.D.
5
top area
weight
55" x 25"
100 lbs.
capacity
68 gal.
V
Hz
A
120
60
10.5
required
1-1/4"
1-1/2"
1/2" R.
INTEGRAL
DROP-IN
FLANGE
RIM
DETAIL
DETAIL
EA
113867-2-
(-)