1. Float valve turns on/off by itself
without toilet being flushed.
2. Float valve continues to run, allowing
water to enter tank.
3. Incorrect water level height.
4. Long or noisy tank fill cycle.
5. Poor flush.
6. Toilet overflows.
7. Toilet does not activate.
1176009-T01-A
A. No slack in flapper chain assembly,
holding flapper off seat.
B. Flush valve flapper ball worn, dirty
or misaligned with flush valve seat;
or seat corroded so flapper will not
seal.
C. Refill tube pushed too far down in
overflow pipe.
A. Foreign particles lodged under the
float valve seal (located under float
valve cap)
B. Float valve seal (located under float
valve cap) may be cracked or split.
C. Tank water level set above overflow
level.
D. Water leaking past flush ball.
E. Trip lever binding, holding flush ball
open.
A. Valve float cup does not contain
enough water to provide required
ballast.
B. Float height incorrect.
A. Plugged valve inlet or supply line.
A. Water level is too low.
B. Trapway or rim holes are obstructed.
C. Soil pipe or vent is obstructed.
D. Supply shut-off valve not fully open.
E. Low water level in bowl due to refill
tube being plugged or out of overflow
tube.
A. Toilet trapway is obstructed.
B. Soil pipe or vent is obstructed.
A. Chain is not connected to lift rod or
flush valve.
-7-
A. Adjust flapper chain assembly for
proper slack.
B. Inspect, clean and, if necessary,
replace flapper ball and/or seat.
C. Attach refill to overflow pipe above
the water line.
A. Shut off water supply; remove float
valve cap assembly by rotating 1/8
turn counterclockwise. Cover
uncapped lower valve unit with an
inverted cup (holding it to
overspray), and turn water on and off
a few times. Clean float valve seal
surface (located under float valve cap).
Replace float valve cap assembly by
engaging lugs and rotating 1/8 turn
clockwise. Turn water on.
Install filter in supply line to prevent
recurring problems.
B. Replace seal.
C.
During fill cycle, hold float under water
a few seconds to allow it to fill with
water ballast. Refer to "Minor
Adjustment of Water Level" for
waterline adjustment.
D. Replace flush ball.
E. Turn trip lever nut clockwise to loosen
until trip lever no longer binds
A. During fill cycle, hold float under water
a few seconds to allow it to fill with
water ballast.
B. Refer to "Minor Adjustment of Water
Level" for waterline adjustment.
A. Perform Corrective Action 2.A.
A. Adjust
tank
water level.
B. Unclog trapway; clean rim holes.
C. Clear obstruction from soil pipe or
vent.
D. Open supply shut-off valve.
E. Clean or straighten refill tube attach
refill tube to overflow tube.
A. Use plunger to unclog.
B. Clear obstruction from soil pipe or
vent pipe.
A. Reconnect the chain.
prevern