If for example the LOCAL unit controls a radiating floor, the HEATER UNIT should be
LOCAL if you wish to heat only with it. You can choose to heat with the air
conditioning if you select REMOTE or even BOTH if you want both to heat at the
same time.
The same applies for the COOLING UNIT. In our example, cooling would be made
with the air conditioning. Therefore the COOLING UNIT should be set to REMOTE.
This setting can be changed any time you like.
If for example you have no cooling unit, then set it to NONE: the thermostat will
not operate in Summer mode.
Puting temporarily both units operating together can be made without setting the
HEATER or COOLER units to BOTH: just hold the key
operation that the second unit will switch on together with the first. Please see the
chapter USING 2 UNITS WITH 1 THERMOSTAT for more details.
This is how you select the HEATER and COOLER units:
SELECT UNIT
HEATER
SELECT UNIT
LOCAL
SELECT UNIT
REMOTE
SELECT UNIT
COOLER
SELECT
UNIT TYP
UNIT TYPE
The thermostat must be configured for the climatization unit it is connected to
because the operation is different for several types of climatization units. You can
choose the following unit types:
RADIATOR
R. FLOOR
AIRFLOW2
AIRFLOW4
AIR CON1
DAIKINFD
AIR CON2
To select the right unit type proceed as follows:
SELECT
UNIT TYP
RADIATOR
AIR-CON1
16:30
Notes:
Press key
(ENTER):
- the display shows the actual unit.
Change with key
(UP) or
Confirm by pressing key
Proceed the same way for the COOLER unit.
When you confirm with key
menu item.
usually wall or floor mounted radiators with water, operation with
on/off of valve
radiating floor with water, proportional operation
air flow unit with 2 tubes, on/off of valve and 3 ventilation speeds
air flow unit with 4 tubes, on/off of heat and cool valves and 2
ventilation speeds with automatic change between Winter and
Summer operation
air conditioning, on/off of compressor and 3 ventilation speeds
DAIKIN air conditioning of series FDX equipped with interface board
KRP413A
air conditioning, on/off of compressor and 3 ventilation speeds but
with delay of 3 minutes to start the compressor
Press key
(ENTER):
- the display shows the actual unit.
Change with key
(UP) or
Confirm by pressing key
- the display shows the time and extis the menu. Remember, the
unit is OFF if the display shows time.
(VENT) on the normal
(DOWN)
(ENTER):
(ENTER) the display will show the next
(DOWN)
(ENTER):
www.a-touch.in.th