AQTRONIC SF53 Operation Manual - Page 2

Browse online or download pdf Operation Manual for Controller AQTRONIC SF53. AQTRONIC SF53 5 pages.

SF53
CNC PLASMA Torch Height Controller
Terminal details:
Direct 1:1 plasma cutters
ATTENTION:When connecting directly, use the
shortest possible cables for connecting the plasma
source with THC controller - it is recommended the
THC controller to be located directly at the plasma
source.
1:1 Plasma Ratio input:
While being a universal THC, accepting full raw arc
voltage for most any plasma cutter on the market, an
exciting new standard feature of this unit is the ad-
dition of a 1:50 divider for an extremely fast, simple
installation on most major brands. There will most
likely be a direct connection for this on the outside of
the plasma cutter's unit. Please refer to your plasma
cutter owner's manual.
An example of how to connect the THC controller's
measurement input withthe output of the very
popular Hypertherm Powermax45 ®- The THC
comesstandard equipped with a low voltage output of
1:50 divider. This ratio is the most commonly used
division in most major brands and there will most like-
ly be a plug for this connection on the outside of the
cutter's unit.
2
http://www.aqtronic.com
Hypertherm Powemax45 1:50 DV