Aqua Computer poweradjust 3 User And Installation Manual - Page 6

Browse online or download pdf User And Installation Manual for Controller Aqua Computer poweradjust 3. Aqua Computer poweradjust 3 20 pages. Usb unit is a high power fan or pump controller for pcs

Aqua Computer poweradjust 3 User And Installation Manual
POWERADJUST 3
for the power output. This setting remains active until it is manually reset through
the aquasuite software or until the device is restarted.
Despite this over temperature protection, the power output is not short-circuit
proof!
Pin assignment:
Pin 1: GND
Pin 2: 0-12 V
Pin 3: Speed signal

5.4. USB

5.4. USB
5.4. USB
5.4. USB
This connector is used for USB communication to the PC and for power supply.
Connect to an internal USB header of your motherboard. Take special care to
make sure the pin alignment matches your motherboard!
Pin assignment:
Pin 1: +5 V(red)
Pin 2: D-
Pin 3: D+ (green)
Pin 4: GND(black)
Pin 5: not connected

5.5. aquabus 1/2

5.5. aquabus 1/2
5.5. aquabus 1/2
5.5. aquabus 1/2
Connector for communication with other Aqua Computer devices. You can use
the aquabus/speed signal cable included in delivery to connect the poweradjust 3
controller board to a suitable connector of a compatible device, for example an
aquaero. USB and aquabus interface can be used at the same time, aquabus data
is processed with higher priority.
Pin assignment:
Pin 1: GND
Pin 2: SDA
Pin 3: SCL
Compatible aquabus devices:
aquaero 6 XT/PRO/LT (art. 53206, 53146, 53145, 53234)
aquaero 5 XT/PRO/LT (art. 53125, 53095, 53090, 53089)

5.6. Flow sensor

5.6. Flow sensor
5.6. Flow sensor
5.6. Flow sensor
Flow sensor and special interconnecting cable are not included in delivery.
Pin assignment:
Pin 1: GND
Pin 2: +5 V
Pin 3: Signal
Compatible flow sensors:
Flow sensor with 5.6 mm nozzle (art. 53061)
Flow sensor "high flow" (art. 53068)
Connection cable for flow sensor (art. 53027)
- 6 -
(white)
Aqua Computer GmbH & Co. KG
Gelliehäuser Str. 1, 37130 Gleichen
aqua
computer
© 2014-2016