Aqua Computer AQUASTREAM XT USB User And Operating Manual - Page 8
Browse online or download pdf User And Operating Manual for Water Pump Aqua Computer AQUASTREAM XT USB. Aqua Computer AQUASTREAM XT USB 16 pages.
Also for Aqua Computer AQUASTREAM XT USB: User And Installation Manual (20 pages)
aqua
computer
The power of the fan connector is put on 100% at a temperature of approx.
70°C to minimize the internal dissipation power. If the temperature increases
nevertheless further, then the performance is put on 0% at a temperature of
approx. 90°C and the connection will be switched off.
In both cases the regulation activates the manual mode until you change the
adjustments by hand.
6.9. Connector pin assignment
Power supply:
Pin 1 +12 V supply
Pin 2 GND
Pin 3 GND
Pin 4 n.c.
Fan output:
Pin 1 GND
Pin 2 0-12 V output voltage
Pin 3 Speed signal
Speed signal output:
Pin 1 GND
Pin 2 n.c.
Pin 3 Open collector speed signal
aquabus/flow rate sensor:
Pin 1 GND
Pin 2 aquabus SDA / flow rate sensor signal
Pin 3 aquabus SCL / flow rate sensor +5 V
USB:
Pin 1 n.c.
Pin 2 GND
Pin 3 D+
Pin 4 D-
Pin 5 +5 V
External sensor:
Pin 1 GND
Pin 2 Measurement signal
Page 8
Aqua Computer GmbH und Co. KG
Gelliehäuser Str. 1 – D-37130 Gleichen - Germany
Version 11/2007
MANUAL AQUASTREAM XT
© 2007