TROUBLE
Fusion does not operate
-OR-
Starts then stops
Fusion spray pattern is not
reaching full size
Fusion Series T roubleshooting G uide
CHECK
Not plugged in
GFCI/RCD Tripped
GFCI/RCD not
tripped,not
running.
Fusion intake clogged
Nozzle clogged
A quatic T echnologies
41 Yazaki Way, Carrum Downs 3201
Ph: (03) 9071 2442
aquaticenquiries.aquatic.net.au
Contact Your Local Distributor
1HP & 2HP Fusion Series Owner's Manual
POSSIBLE SOLUTIONS
Cord must be plugged into a 3-wire outlet
that is protected by a GFCI (Ground Fault
Circuit Interrupter).
Reset GFCI/RCD. If GFCI/RCD will not
reset or trips immediately, unplug the pump
& lights and reset GFCI/RCD. If GFCI/RCD
will still not reset, there may be a problem
with the incoming power. If the GFCI/RCD
resets, plug the pump. If the GFCI/RCD
trips, there may be a problem with the pump
cord. If the GFCI/RCD holds, plug in the
optional light kit. If the GFCI/RCD trips,
there maybe a problem with the lights.
Contact Aquatic Technologies Technical
Support totroubleshoot lights or
Disconnect power. Check propeller for
obstruction. These motors have internal
overloads. If the propeller is jammed, the
internal overload may trip. This overload
may require up to 10 minutes to cool down
& reset. If the motor does not restart, there
may be other motor problems. Contact
Aquatic Technologies Technical Support to
troubleshoot the pump.
Disconnect power. Check suction screen for
obstruction & remove debris.
Disconnect power. Remove nozzle &
check for obstruction & remove debris.
-OR-
pump.