7. DRYER IGNITION (SOLID STATE IGNITION): The solid state ignition system lights the main burner gas by spark.
The gas is ignited and burns only when the gas-relay (in the electronic controller) calls for heat. The procedure for first-time
starting of a dryer is as follows.
A. First review and comply with the "Warnings About Use and Operation" found on the inside front cover of this
manual. Be sure electrical power is connected correctly. The dryer must be properly grounded.
B. Make sure all gas supply lines are purged of air. Close the main gas shut-off valve and wit for five minutes
before turning it back on.
C. Turn on the main electrical power switch. The dryer may be started by following the "Operating Instructions"
found later in this manual.
D. Natural gas and LPG fired dryers operate in the same manner. When the gas valve relay contacts are closed
(indicating a demand for heat), the solid state ignition control will automatically supply energy to the redundant gas
valve. Sparking will continue until a flame is detected by the sensing probe, but not longer than ten seconds. If the
gas fails to ignite in 10 seconds, the gas valve closes and the gas system pauses to allow gas to purge from the inside
of the dryer. After the pause, the ignition control repeats the ignition trial cycle twice more. If the gas system fails
to detect ignition after the three attempts, the system will "lock out". No further attempts will be performed
automatically. To reset the ignition control electrical power to the ignition control must be interrupted. This can be
done by opening the dryer door (stopping the dryer) for 15 seconds. Closing the door and pushing the "Start" button
will repeat the ignition trial cycle.
8. MAIN BURNER ADJUSTMENT. The primary air shutter of each main burner must be properly adjusted for the correct
air-gas ratio. Loosen the shutter locking screw. Adjust the shutter by closing it sufficiently to give a blue flame with a
yellow tip. Next open the shutter until the yellow tips are at a minimum. After adjustment securely lock each shutter in
position by tightening the shutter locking screws.
To render the dryer inoperative, turn off the main gas shut off valve and disconnect the electrical supply to the dryer.
Both drums are controlled by the controller at the right midpoint of the dryer. The controller is two-in-one with the upper
display and lights dedicated to the upper drum and lower display and lights dedicated to the lower drum.
The green light to the left of the display flashes to indicate money has been deposited. Time is not added until the upper or
lower drum is selected. If no purchased time is available on the control, the vend price is displayed. At the end of the cycle
(when time has expired), the displays flash until the door is opened.
The drying program (temperature) selected by the user are indicated by the red lights at the top and bottom. When the dryer
is in use, the drying temperature may displayed by simultaneously pressing the start switch and switch of the temperature
selected.
All programmed data and cycle time remaining are protected from power interruptions of any length.
Some Dexter dryers are factory equipped with a card reader that is used with Dexter's Easy Card debit card system. The card
reader signals the dryer control when money is debited from the user's card account to satisfy the price of the dry time. The
dryer's pricing and the Easy Card system pricing are completely independent of each other and must be separately
programmed and coordinated. Refer to the instructions that came with the Easy Card system for complete information.
8

DRYER SHUTDOWN

DESCRIPTION OF CONTROLS

EASY CARD MODELS