Designed to be maintenance free, the AV23 requires minimal attention, though the following
maintenance and servicing information is provided to help ensure the life of your Avlite product.
1. Cleaning Solar Panels - occasional cleaning of the solar panels may be required. Using a cloth and
warm soapy water, wipe off any foreign matter before rinsing the panels with fresh water.
2. Battery Check - inspection of batteries should be performed every three years (minimum) to ensure
that the charger, battery and ancillary electronics are functioning correctly. Using a voltage meter,
check that the battery voltage is at least 3.6 volts under 100MA load, and ensure all terminals are
clear of foreign matter.
Replacing the battery- Don't throw the unit out!!
The AV23 light battery compartment provides the user with the ability to change the battery after years of
operation.
1. Remove the 2 x M8 x 50 SHCS.
2. Remove battery from AV23 case and disconnect the battery leads.
3. Discard old battery in a safe manner.
4. Reattach positive and negative leads to new battery and then place back into case.
5. Refit the light head. Tighten SHCS evenly and securely.
6. To test place dark cover (towel or jacket) on top of light to activate sensor, light will come on.
Care must be taken to observe the polarity of the battery before the leads are re-connected, and
ensure the replacement battery is correctly fitted. Always discard old batteries in a safe manner.
Long Term Storage Instructions
If the AV23 is to be placed in storage for an extended period, being more than 5 months, please follow
the below steps.
1. The 12 volt SLA Battery must be stored in a fully charged condition.
2. Remove the light head.
3. Disconnect the battery leads.
All batteries will discharge over time and the rate of discharge is dependent on temperature. If the light is
being stored in temperatures greater than 40°C the battery will discharge faster.
Please check battery every 3-6 months and recharge if necessary.
Recharging the Battery
1. Remove the light head and assembly.
2. Connect the battery leads.
3. Reconnect the battery and place unit in the sun for 2-4 days
Or
Reconnect battery and place in front of a halogen lamp for 2-3 days. (Do not place the halogen light too
close to the solar panel or the panel may be overheated)
Check the battery voltage regularly to make sure the unit is charging correctly.