2VV VCB-A-090-E-RF-0-0 Manual - Page 5

Browse online or download pdf Manual for Heater 2VV VCB-A-090-E-RF-0-0. 2VV VCB-A-090-E-RF-0-0 11 pages. Electric door heater

2VV VCB-A-090-E-RF-0-0 Manual
2. UNPACKING
2.1 CHECK THE DELIVERY
DO NOT OVERLOOK
Check immediately after delivery that the packed product has not been damaged. If the packaging is damaged inform the carrier.
If the complaint is not lodged in time, no future demands can be claimed.
After unpacking from the box, check whether:
1. The designation on the box corresponds with the rating label on the door heater.
2. The door heater is mechanically damaged.

3. OPERATING CONDITIONS

DO NOT OVERLOOK
The compact heater is designed for transferring air free of coarse dust, fats, chemical vapours and other pollutants, etc.....
The heater has an IP 20 protection class and can work in an environment with an ambient temperature of +5°C to +40°C.
The suction inlet and the exhaust outlet must not be blocked by anything.
Placing any items on to the body of the heater is not permitted.
The electrical power socket must be located no further than 1.5 m from the heater.
For the heater to operate properly, there must be at least 150mm of free space in front of the suction inlet cover.

4. TECHNICAL PARAMETERS

TECHNICAL INFORMATION
Air power
[m3/h]
Type
max
min
speed
speed
VCB-A-060-E-
315
285
RF-0-0
VCB-A-090-E-
475
410
RF-0-0
** Acoustic pressure measured at 3 and 5 m away from the device at maximum motor speed. Direction coefficient Q:2.

5. INSTALLATION

The electric door heater offers a wide range of applications. Therefore it is possible to install this heater above the door, above the
store windows and on the wall. For installation, follow the instructions provided below. Due to the fact that this is a heating device,
basic heating rules should be adhered to. For the calculation of the heating source requirements it is necessary to include the
heater among the heating sources of the building's heating system.
Acoustic pressure
Voltage /
[dB(A)]**
Frequency
current
[V/Hz]
3m
5m
46,5
42,1
230 / 50
48,5
44,0
230 / 50
Fan
Fan power
Heater
Total con-
input
power
sumption
[A]
[W]
[kW]
[A]
0,4
57,0
2,4
11
0,7
87,0
3,1
14
1x
1x
Total power
Increasing air
input
temperature
[kW]
Δt [°C]
2,5
22,0
3,2
19,0
Weight
[kg]
6
8
5