Anchor Installation: Core-Drill Retro-Fit

NOTE: FOR DECKS 6" THICK OR MORE, 2500PSI MINIMUM STRENGTH CONCRETE REQUIRED
You will need:
• Core drill and 1½" core drill bit
• Tape measure
• Marking pen
• Hammer
• Cold chisel
• Torpedo level
• High strength 2-part construction epoxy*
• Masking Tape
• Black electrical tape (optional)
• Anti-Seize packet
*Aqua Creek recommends either Hilti™ Brand HIT RE-500-
SD or Simpson™ brand SET-XP or equivalent
FIGURE 2
NOTE: Your local bonding regulations may require you to drill one hole larger than the others in order to bond at
least one of the anchor inserts. You may need to saw cut a portion of your deck.
See "Saw Cutting Retro-Fit Instructions" on page 6.
Remove the nuts and the black protective coverings from the threaded anchor inserts.
3.
4
Copyright © 2018 Aqua Creek Products All Rights Reserved
(not included)
Anchor jig plate with hardware
Mark the 4 hole locations on your deck using
1.
the larger holes of the anchor jig plate as a
template. Make sure the center of the holes on
the anchor jig plate are 14.5 to 19 inches from the
pool's edge.
SEE FIGURE 2
Drill the 4 hole locations to about 4 1/2 inches
2.
deep using the 1 1/2 inch drill bit. Make sure the
holes are completely dry and clear of debris.
NOTE: Create a depth marker on the drill bit with black
electrical tape to make sure you drill to the right depth.
Revised 6/1/18