Aqua Guard SandMaster SM16102S Owner's Manual - Page 8
Browse online or download pdf Owner's Manual for Water Filtration Systems Aqua Guard SandMaster SM16102S. Aqua Guard SandMaster SM16102S 12 pages.
Trouble Shooting
Above normal
Scoring or jamming with foreign matter or debris. If
or excessive
this condition persists after rinsing, disassemble the
force to operate
valve to clear. Continued operation of the valve may
the Multi-Port
result in a non-sealing condition (damage to spider
Valve
gasket). This will lead to water loss
to the backwash line or to inefficient filtration.
Dirty Water
1. Insufficient filtration time.
2. Heavy contaminants or dirt load.
3. Dirty filter, requires backwashing.
4. Air leaking on suction.
5. Pump impeller vanes blocked.
6. In sufficient water supply
(water level low, blockage).
7. Pump not primed.
8. In correct water chemistry.
9. Excessive flow of water for filter size. Foreign matter
or debris forced through filter bed and through the
under drain.
10. Other restrictions including (pool suction cleaners)
resistance from other inline equipment such as
strainers. Operating the filter on recirculate will
determine if the restriction is in the filter.
11. Clogged or channeled filter media. Perform
backwash or regeneration.
Refer to maintenance section.
Winterizing
1. Completely drain tank by unscrewing drain cap at the base of the filter tank. Leave cap off during winter.
2. Depress control valve handle and rotate to set pointer on valve top between any two positions. This will allow water to drain
from the valve. Leave valve in this "inactive" position.
3. Drain and winterize pump according to pump instructions.
aquaguardpoolsystems.com
8
Filter Media in
1. Excessive quantity of media in
the backwash
the filter.
2. Excessive water flow.
3. Incorrect sized or grade of filter
media.
Filter Media
1. Filter is on recirculate.
returning to
2. Verify it is the filter media and
Swimming
not from another source.
Pool/ Spa
3. Damage to the under-drain
laterals.
4. Damage or incorrect fit of
Multi-Port Valve are correct.
5. Incorrect or mixed grades of
media in the filter.
Short filtration
1. Presence of algae or a scale
cycles
builds up.
2. Check water chemistry.
3. Excessive water flow, check
pump size, mains water flow.
4. Filter blocked through calcium