SNMP works fine after restore configuration.
Time stamp for data buffering does not change after appliance‟s reboot (L3-65572461)
Appliance‟s console banner shows the version of the firmware after upgrade process (L3-
65568595).
NTP works fine after restore configuration (L3 65577141).
Telnet Send Break command sends the break signal to the target device. (L3 65582372).
In CLI, the option "-C" allows customer to execute CLI command in no-interactive mode.
(L3-65589589).
SNMP community name supports special characters. (L3-65602362).
The SNMP answer for sysObjectId is the Product Object ID.
The logging configuration depends of the configuration of Data Buffering, ie, the logging
configuration will be effective only if Data Buffering status is configured as „enabled‟. (L3-
65605084).
The syslog message header shows only the host name of the appliance. (The string
„src_dev_log@‟ was removed from the syslog message).
CPU info shows the correct processor name: 440EPX.
ACS 6000 console server supports chain of PM10/20 30A with version 1.9.1.
======================================================================
======================================================================
This release contains the following known issues:
Firmware Upgrade for a PDU under Power Management > PDU node has the following
restrictions:
o Multi-selection is available only for PDU (PM x000 PDU family)
o May return error when more than one PDU is selected for the operation. In this case
click in the Power Management > PDU node in the left menu. The status of a PDU
will show up as „Not Available‟. Wait some minutes and click in the node again.
When the status change to „On line‟, select the PDU again and click reboot (PDU
requires reboot after firmware upgrade).
Wireless LAN devices (PCMCIA cards 16/32 bits and USB) are not supported.
NIS, IPSec and NFS data logging are supported over IPv4 only.
The outlet table under PDU Devices drill-down in the Web is not automatically refreshed
after a cycle action for SPC power devices and ServerTech PDUs. The user needs to click
the refresh button.
Changes in configuration related to session (including Idle Timeout and Appliance Session
Data Logging) are only effective on the next login.
To use keys in SSH sessions, the authentication type should be configured as local.
In CAS profile, the options for Auto Discovery and Auto Answer are mutually exclusive.
Both cannot be enabled in the CAS Profile configuration for one port. If Auto Answer is
selected in the Serial Port 1, Auto Discovery cannot be configured in the Serial Port 1,
because both features work with probes and matches though in a different way.
o Auto Answer tries to match the input. When it matches, it sends the output string
o Auto Discovery sends the probe string and waits for the input to match with the
match string that will handle the target name.
Known Issues