Other Maintenance:

Replace the Ballast:
Unplug UV sterilizer from outlet.
Remove screws from UV lid and front cover,
remove the both covers.
Place new ballast near UV.
Remove screws which hold ballast to unit.
Remove old ballast.
Mount new ballast with screws.
Strip approximate ¾-inch insulation from ends of
red and blue wires on ballast and on bulb
connector assemblies.
Replace UV sterilizer lid and front cover. Install
screws.
Apply power to UV sterilizer.
The view port should show a blue light after a few seconds.