Other Maintenance:
Replace the Ballast:
•
Unplug UV sterilizer from outlet.
•
Remove screws from UV lid and front cover,
remove the both covers.
•
Place new ballast near UV.
•
Remove screws which hold ballast to unit.
•
Remove old ballast.
•
Mount new ballast with screws.
•
Strip approximate ¾-inch insulation from ends of
red and blue wires on ballast and on bulb
connector assemblies.
•
Replace UV sterilizer lid and front cover. Install
screws.
•
Apply power to UV sterilizer.
•
The view port should show a blue light after a few seconds.