REMOVING ORGANICS FROM THE UV:
WARNING: Be sure to wear protective gear for your hands and eyes!!
Turn UV power switch off on control box.
Disconnect UV from plumbing and drain it.
Make a pure chlorine bleach solution (1 cup bleach to 1 quart
water)
Connect the flush kit hoses to the inlet and outlet of the UV sterilizer
or to the drain and flush kit inlet (if available).
Cycle the solution through the UV sterilizer for 5-10 minutes.
Drain the bleach solution from the UV sterilizer.
Rinse or flush the unit thoroughly to remove all chlorine. Continue to flush until you can no longer
smell chlorine. You may wish to add a few drops of a dechlorinator to insure that all chlorine has
been neutralized.
Reconnect the UV to the plumbing.
Replace UV sterilizer lid and install screws.
Turn pump on.
Apply power to UV sterilizer.
The view port should show a blue light after a few seconds.
REMOVING MINERAL DEPOSITS FROM THE UV:
WARNING:
Be sure to wear protective gloves and goggles!!
DO NOT COMBINE chlorine bleach with muriatic acid or equivalent. The resultant
gases may be poisonous.
Follow procedure as above except that you use muriatic acid or equivalent. Be sure to follow
product instructions carefully.
©2004 Aqua Logic,® Inc. 8268 Clairemont Mesa Blvd. Suite 302 San Diego, CA. 92111
Ph (858) 292- 4773 FAX (858) 279-0537 email: [email protected] website: www.aqualogicinc.com

Parts Listing:

All replacement parts are available directly from Aqua Logic, Inc.
Bulbs:
ALA-36 Watt Bulb
Ballast:
ALB-36 Watt Self-Starting Ballast
Quartz Sleeve:
ALQ-36 Watt Quartz Sleeve Assembly
Miscellaneous:
Bulb Pin Connector Assembly
Page 7