DeZURIK
LIFT, TURN AND RESEAT G-SERIES ACTUATORS USED ON
PTW & PFW TAPERED PLUG VALVES
Recommended Spare Parts Replacement
17. Pack the gear sector teeth with lubricant, then slide the gear sector into the bearing, making
sure it is in the position noted before it was removed.
18. Place a new gasket on the actuator housing, then set the cover on the unit, lining up the scribe
lines made during disassembly.
19. Set the dial cover in place. Install, but do not tighten, the four screws.
20. Install the actuator on the valve as described in the ACTUATOR INSTALLATION Section of this
Instruction.
21. Check the stop settings and readjust if necessary. The correct adjustment procedure is
described in the STOP ADJUSTMENT Section of this Instruction.

Changing Actuator Mounting Positions

The actuator can be mounted in 60° increments around the valve stem. To change the actuator
mounting position, follow these steps.
1. Remove the actuator from the valve as described in the ACTUATOR REMOVAL section of this
Instruction.
2. Rotate the actuator to the desired position.
3. Install the actuator on the valve as described in Steps 3 thru 10 of the ACTUATOR
INSTALLATION section of this Instruction.
Changing Combination Numbers on PTW Valve
If combination number needs to be changed, call field service to request Instruction Y99722.
May 2020
(continued)
Page 8
D10189