Replacing the Gate
11. On KGC-BD valves, powered actuators should be set-up to avoid excessive compression of the
perimeter seat when closing the valve. To accomplish this, have the cylinder actuator fully ex-
tended and the clip holes aligning with the gate when it is fully down into the valve. Then, retract
the actuator and thread the clip outward two revolutions. After this, the clip can be attached to the
gate.
12. Adjust the actuator, yoke, and packing gland so that the valve actuates smoothly full stroke in both
directions, and so that there is no evidence of binding or scratching on the gate when the gate is
visible in the fully open position.
13. Reinstall the valve in the pipe line —see "Installation" section.
14. If the actuator is a powered actuator, reconnect power to the actuator.
15. Pressurize the pipeline and inspect the valve for leaks.
16. If the packing leaks, tighten the adjustment nuts (A7) on top of the packing gland.
Note: Tighten the nuts evenly and slowly, just enough to stop the leakage. Over tightening will cause
excessive operating forces, and will decrease the life of the packing.
Troubleshooting
Packing leaks, with no evidence
of galling on gate
Packing leaks and gate is galled
Valve leaks when fully closed,
with no evidence of galling on
Valve leaks when fully closed
D11050
continued
Condition
gate
Possible Causes
Packing is loose
Packing is worn or torn
Packing is worn or torn
Seat is worn or torn
Seat is worn or torn
Page 12
DeZURIK
Corrective
Action
Adjust packing gland
Replace packing
Replace packing and
gate, check seat for
damage or wear
Contact DeZURIK if
seat replacement is
required
Contact DeZURIK if
seat replacement is
required, check gate
condition
July 2018