Aqua Lung Octopus Maintenance Manual - Page 15

Browse online or download pdf Maintenance Manual for Controller Aqua Lung Octopus. Aqua Lung Octopus 20 pages. Second stage
Also for Aqua Lung Octopus: Technical Bulletin (4 pages)

Aqua Lung Octopus Maintenance Manual
Calypso/Titan Second Stage Service Manual
Table 4 - Recommended Lubricants & Cleaners
LUBRICANT / CLEANER
Christo-Lube
MCG-111
®
CAUTION:
DO NOT apply grease or spray to silicone rubber parts. Doing so may cause a
chemical breakdown and premature deterioration of the material.
Oakite #31
White distilled vinegar
CAUTION:
strongly diluted, muriatic acid can harm chrome plating and may leave a resi-
due that is harmful to O-ring seals and other parts.
Liquid dishwashing detergent
(diluted with warm water)
APPLICATION
All O-rings seals
Silicone rubber requires no lubrication or preservative treatment.
Acid bath for reusable stainless
steel and brass parts.
Acid bath for reusable stainless
steel and brass parts.
Do not use muriatic acid for the cleaning of any parts. Even if
Degreaser for brass and stainless
steel parts; general cleaning solu-
tion for plastic and rubber
SOURCE
Aqua Lung, PN 820466, or
Lubrication Technologies
310 Morton Street
Jackson, OH 45640
(800) 477-8704
Oakite Products, Inc.
50 Valley Road
Berkeley Heights, NJ 07922
"Household" grade
"Household" grade
15