6
Attention: The valve holders should be
fitted so that the gas can circulate in the
direction indicated by the arrows engraved
on the mouthpiece body.
5.
Insert the O-ring (6) into the mouthpiece body to the left
of the sticker.
6.
Fit the O-rings (6) to the two connectors (3).
7.
Lubricate the two O-rings and the surface in contact
with the mouthpiece body using a brush.
8.
Fit the connectors into the mouthpiece body
Note: Check that the connectors are correctly
fitted.
9.
Screw the two screws completely home by hand.
Mistral Mouthpiece Service Manual
10. Fit the moulded mouthpiece (9) then the mouthpiece
clip (8).
11. Fit the lip guard
12. Check the condition of the two corrugated hoses, they
should not show any cuts or any other signs of
deterioration.
If they are in good condition, it is not necessary to replace
them and they can be reused. If they show any signs of
deterioration they should be replaced and refitted following
the procedure described in the Mistral Second Stage Service
Manual.
13. Place the corrugated hoses onto the connectors and
proceed as follows:
a.
Fit the corrugated hoses to the connectors.
Attention: The corrugated hoses should be
fitted to the connectors so that the gas can
circulate in the direction indicated by the arrows
engraved on the mouthpiece body.