Avocent Direct PDU DPDU103 Specifications - Page 2
Browse online or download pdf Specifications for Power Supply Avocent Direct PDU DPDU103. Avocent Direct PDU DPDU103 2 pages. Intelligent power device
Features
Built in on-board Web interface for
simplifi ed management
Independent control of each power port
(power on/off)
Current meter and over current alarm
Audible alarms, SNMP and email
notifi cation when consumption thresholds
are reached
Software utility to monitor multiple
Direct_PDU power devices from a single
interface
Input
Input voltage
Branch Circuit Rating
Input connector
Output
Max. output current per outlet
Output connector
Number of Outlets
Interfaces
Network port
Physical
Mounting
Width
Depth
Height
Weight
Environmental
Operating temperature
Storage temperature
Certifi cations
FCC, UL, cUL, CE, C-Tick
Sequential power up to prevent current
overload
Built in circuit breaker
10/100Base-T Ethernet port
LED display on each port for visual status
Horizontal and vertical mounting options
DPDU101
DPDU102
15A
20A
100-120V
100-120V
NEMA 5-15P
NEMA 5-20P
15A
20A
NEMA 5-15/20r
NEMA 5-15/20r
8
16
10/100
10/100
Vertical
Vertical
23 in (9.06 cm)
49.02 in (19.30 cm) 17.01 in (6.7 cm)
1.5 in (0.59 cm)
1.74 in (0.69 cm)
2.21 in (0.87 cm)
2.21 in (0.87 cm)
4.2 lb (1.91 kg)
8.4 lb (3.82 kg)
32° F to 104° F
32° F to 104° F
(0° C to 40° C)
(0° C to 40° C)
5° F to 122° F
5° F to 122° F
(-15° C to 50° C)
(-15° C to 50° C)
✓
✓
www.avocent.com/contacts
On Board Web Interface
Direct_PDU power device
DPDU103
DPDU201
15A
16A
100-120V
200-240V
NEMA 5-15P
IEC 320
15A
10A
NEMA 5-15/20r
C13r
8
8
10/100
10/100
Horizontal
Vertical
23 in (9.06 cm)
3.55 in (1.4 cm)
1.5 in (0.59 cm)
1.74 in (0.69 cm)
2.21 in (0.87 cm)
5.08 lb (2.31 kg)
4.2 lb (1.91 kg)
32° F to 104° F
32° F to 104° F
(0° C to 40° C)
(0° C to 40° C)
5° F to 122° F
5° F to 122° F
(-15° C to 50° C)
(-15° C to 50° C)
✓
✓
Avocent, the Avocent logo and Direct_PDU are trademarks or registered
trademarks of Avocent Corporation or its affi liates in the U.S. and other countries.
All other marks are the property of their respective owners.
Copyright © 2009. Avocent Corporation.
Direct_PDU
n te r
r
C e n te
a ta C e
S M B D
S M
DPDU202
DPDU203
16A
16A
200-240V
200-240V
IEC 320
IEC 320
10A
10A
C13r
C13r
16
8
10/100
10/100
Vertical
Horizontal
49.02 in (19.30 cm) 17.01 in (6.7 cm)
1.74 in (0.69 cm)
3.55 in (1.4 cm)
2.21 in (0.87 cm)
1.74 in (0.69 cm)
8.4 lb (3.82 kg)
5.08 lb (2.31 kg)
32° F to 104° F
32° F to 104° F
(0° C to 40° C)
(0° C to 40° C)
5° F to 122° F
5° F to 122° F
(-15° C to 50° C)
(-15° C to 50° C)
✓
0209-DirPDU-DS-EN
Direct_PDU power device
✓