Fault finding
SYMPTOMS
CAUSE
Unit lifts when pumped
Airlock.
but lowers when the
handle returns to the
rest position.
Unit will only lift a few
Lack of oil.
inches.
Oil leakage.
Worn or damaged
seals.
Load slipping on toe
Worn or damaged
plate.
rubber mats.
Load incorrectly
strapped.
Toe plate bent.
CARE & MAINTENANCE
Regularly check for wear and defects
such as...
If a top-up of hydraulic oil is required use only
Total Oil (UK) Ltd hydraulic oil Azolla ZS.32.
NEVER USE ENGINE OIL OR BRAKE FLUID
Store SKOOTS upright whenever possible
with release valve left in the open position.
In case of difficulty contact...
BIL Materials Handling, Porte Marsh Rd, Calne, Wilts. SN11 9BW
Tel: +44(0)1249 822222 Fax: +44(0)1249 822300
REMEDY
Release the valve wheel one quarter
turn and pump handle vigorously 20 to
30 times.
For SK300N replace jack. For other
models fully retract jack and remove
filler plug, top up with Total Oil Azolla
ZS.32 oil up to 25mm from top. Extend
jack 330mm, refit plug and then
retract jack. Ready for use.
Jack should be serviced or replaced
with a new exchange unit.
Replace rubber mats.
Check straps are correctly fitted and
pulled tight.
Fit new toeplate.
– stress cracks and broken welds
– loose and missing fasteners
– castor wear, especially tyres
– rubber mats
– straps