Aqua Medic Easy Line 90 Operation Manual - Page 3

Browse online or download pdf Operation Manual for Water Filtration Systems Aqua Medic Easy Line 90. Aqua Medic Easy Line 90 6 pages. Reverse osmosis unit

Aqua Medic Easy Line 90 Operation Manual
2. Set-Up
To fix the unit at a wall, disconnect the 2 wall clamps from the module and fix them directly
on the wall or on a mounting plate - preferably near a tap connection. Press the module into
the clamps - ready.
Then mount the membrane and connect the tubes. To avoid any failures, follow
instructions carefully:
Tube Fittings:
- Put the nut and the small ring on the tube.
- Push the tube tight into the fitting and fix the nut.
The connections of the unit are:
1. connection between sediment filter and module
2. tap water inlet - into the sediment filter
3. concentrate outlet (waste water) at the flow restrictor
4. pure water (permeate)
5. tap water connection
Fix the water connection piece to a 3/4" water cock. If it does not fit, use a reduction piece
(not included).
1
2
3
Reverse osmosis unit...
Mounting of the membrane:
Remove the screw cap from the module housing (fig 1, 7).
Take the membrane from the plastic bag and put it into the
menbrane housing. Take care to insert the membrane in the right
direction, with both sealings (1) directed to the water outlet. The
membrane has to be pushed forward, until the 2 sealings are inthe
right position at the top and the big pure wastewater seal ( 3) is
fixed. Now the housing can be closed again.
3. Starting
When all connections are tight, you can open the tap faucet. The
minimum water pressure for the unit is 3 bar. The nominal
capacity is reached at 4 bar. If the pressure drops below 3 bar, the
production capacity is reduced, below 2 bar it reduces also the
reduction rates.
Firstly, check all connections on water tightness. If leakage occurs,
tighten the fittings or the housing.
Now the concentrate flows out of the outlet. After some minutes
also the purified water flows out of the permeate outlet, however,
with a lower flow rate.
Flow Rate (Liter/Hour) at 4 bar and 15° C
Pure water/permeate
Waste water/concentrate
the