CP EBDHS-DD-LT30 Product Manual - Page 7
Browse online or download pdf Product Manual for Security Sensors CP EBDHS-DD-LT30. CP EBDHS-DD-LT30 13 pages. Ceiling pir hs presence detector–dali/dsi, low temperature
Two channel, individual switches
Functions: Switches both channels with occupancy. Maintains illuminance, dims and switches the dimming channel
using optional single position retractive switch (switch 2). Switches the switching channel using the optional single
position retractive switch (switch 1).
Configured to presence detection: Turns on automatically with occupancy. Maintains illuminance (dimming channel
only). Press and release switch to toggle output. Press and hold switch to dim up and down (reverses direction with
each press). Turns off after occupancy.
Configured to absence detection: Press and release switch to turn on. Maintains illuminance (dimming channel only).
Press and release switch to turn off. Press and hold switch to dim up and down (reverses direction with each press).
Turns off after occupancy.
Channel mode: Set to "Switch and dim separate"
Switch mode: Set to "1 position switch separate"
PLEASE NOTE THAT THE
DIMMING SIGNAL IS USED TO
SWITCH THE DIMMING
LUMINAIRE ON/OFF AND
THEREFORE THE 240V FEED
TO THE LUMINAIRE FITTING
MUST COME FROM THE
PERMANENT LIVE SUPPLY
NEUTRAL
LIVE
CIRCUIT PROTECTION
EXTERNAL CIRCUIT
(IF REQUIRED)
PROTECTION 10A
Two channel, single switch
Functions: Switches both channels with occupancy. Maintains illuminance, dims and switches the dimming channel
using optional centre biased retractive switch .
Configured to presence detection: Turns on automatically with occupancy. Maintains illuminance (dimming channel
only). Press and release down switch to turn off. Press and release up switch to turn back on. Press and hold up switch
to dim up, press and hold down switch to dim down. Turns off after occupancy. Channel 1 does not operate with switch.
Configured to absence detection: Press and release up switch to turn on. Maintains illuminance (dimming channel
only). Press and release down switch to turn off. Press and hold up switch to dim up, press and hold down switch to dim
down. Turns off after occupancy. Channel 1 does not operate with switch.
Channel mode: Set to "Switch and dim separate"
Switch mode: Set to "2 position switch separate"
PLEASE NOTE THAT THE
DIMMING SIGNAL IS USED TO
SWITCH THE DIMMING
LUMINAIRE ON/OFF AND
THEREFORE THE 240V FEED
TO THE LUMINAIRE FITTING
MUST COME FROM THE
PERMANENT LIVE SUPPLY
NEUTRAL
LIVE
CIRCUIT PROTECTION
EXTERNAL CIRCUIT
(IF REQUIRED)
PROTECTION 10A
N
DIM-
L/OUT
DIM+
L
SW1/UP
SW2
DOWN
EBDSPIR-DD SENSOR
N
DIM-
L/OUT
DIM+
L
SW1/UP
SW2
DOWN
EBDSPIR-DD SENSOR
PLEASE NOTE THAT THE CENTRE BIASED RETRACTIVE
SWITCH WILL PROVIDE CONTROL FOR THE DIMMING
LUMAIRE(S) ONLY. THE NON-DIMMING LUMINAIRE(S) WILL
BE CONTROLLED ONLY BY THE SENSOR
DIMMING
BALLAST
LUMINAIRE
DIMMING LUMINAIRE
(NON-DIMMING)
(DSI or DALI)
DIMMING
BALLAST
LUMINAIRE
DIMMING LUMINAIRE
(NON-DIMMING)
(DSI or DALI)
CENTRE BIASED
RETRACTIVE SWITCH
(240V SWITCHING)
Optional for presence,
mandatory for absence detection
SWITCH 1 - MOMENTARY
PUSH TO MAKE SWITCH
(240V SWITCHING)
Optional for presence,
mandatory for absence detection
SWITCH 2 - MOMENTARY
PUSH TO MAKE SWITCH
(240V SWITCHING)
Optional for presence,
mandatory for absence detection
7