Aqua Medic T controller twin Operation Manual - Page 6

Browse online or download pdf Operation Manual for Control Unit Aqua Medic T controller twin. Aqua Medic T controller twin 9 pages. Digital temperature monitor and controller for controlling heating and cooling units
Also for Aqua Medic T controller twin: Operation Manual (13 pages)

Aqua Medic T controller twin Operation Manual
When the setpoint plus adjusted alarm value is exceeded, you hear a beep. This value is also adjusted
by the arrow keys. By pressing the "SAVE" key the settings will be saved. As soon as the adjusted
setpoint falls below the adjusted value of the control precision, the unit activates the power socket
No. 2 and switches on the consumer (heating). When the adjusted temperature is exceeded, the unit
activates power socket No. 1 and switches on the consumer (cooling).
Example: The setpoint is set to 25° C, the cooling and heating control precision at 0.5° C. As soon
as the temperature rises to 25.5° C (setpoint + control precision) the cooling unit starts. As soon as
the temperature drops below the
If the temperature drops to 24.5° C
the temperature rises more than to the
SET+▲:
By pressing this key combination for several seconds, the display can be turned off or on steadily
(then the display shows „On"). However, constant display illumination reduces the service life of the
display.
SAVE+▲: Reset. The controller is reset to manufacturer's settings.
▲+▼: By pressing this key combination for several seconds, you get to the switching mode of C
(Celsius) and F (Fahrenheit). Use the arrow keys to change the setting.
By pressing the SAVE-key, the required setting is saved.
A minimum deactivation of 3 minutes prevents heating and cooling work against each
other.
The T controller twin has got a rechargeable battery so the programmed data will not be
lost in case of power failure. After starting the unit up, it takes about 24 hours until the
battery is charged and the data remain stored.
For safety reasons, you should control the nominal values, especially after a power failure.
5. Technical Data
Display:
Measurement range:
Resolution:
Loading capacity of contact:
Adjustment range:
Adjustment accuracy:
Power requirements:
Humidity:
6. Warranty
Should any defect in materials or workmanship be found within 24 months of the date of purchase
AB Aqua Medic undertakes to repair, or at our option replace, the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid. Proof
of Purchase is required by presentation of the original invoice or receipt indicating the dealer's name,
the model number and date of purchase. This warranty may not apply if any model or production
number has been altered, deleted or removed, unauthorised persons or organisations have executed
repairs, modifications or alterations, or damage is caused by accident, misuse or neglect. Please note
that the product is not defective under the terms of this Warranty where the product, or any of its
component parts, was not originally designed and / or manufactured for the market in which it is
used. These statements do not affect your statutory rights as a customer.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
Current manuals are available for download at www.aqua-medic.de.
6
setpoint
(here 25° C) the cooling unit will stop.
(setpoint
- control precision) the heating unit starts. As soon as
setpoint
(here 25° C) the heating unit will stop.
0.1° C
0 up to 50° C
0.1° C
1,200 watts at 220 V AC
16 – 40° C
+/- 0.1° C
220 – 240 V, 50 Hz
< 85%
- Technical changes reserved – 06/2018