Accessing The Impeller
1. Turn the pump off at the main power supply and
remove it from the water.
2. Remove the strainer cover from the front of the pump.
To do this hold the motor with one hand and simply pull
the cover away from the motor.
3. Now you must remove the impeller cover. Turn the
impeller cover lock anti clockwise and remove.
4. Pull the impeller cover away from the motor. This will
be a tight fit.
5. Clasp the impeller blades with needle nose pliers
and slowly pull the impeller from the impeller chamber.
6. Clean impeller under warm running water. Do not
use soap or detergent. Remove the rubber end caps
and ceramic shaft and run clean water through the hole
in the centre of the impeller.
7. Use an Aqua One double ended pipe brush to clean
the impeller chamber thoroughly. (Where the impeller
sits in the motor)
8. Please ensure the impeller chamber is free from
debris before reassembling the pump, failure to do so
could damage your pump.
9. Ensure both rubber end caps are in the correct
position. If they do not come out when the impeller is
removed one should be in the impeller chamber and
the other in the impeller cover. Failure to position them
correctly will result in your pump being damaged.
10. Do not force the unit back together as the ceramic
shaft may break. If it does not reassemble easily check
the position of the rubber end caps, ceramic shaft and
impeller.
11. Check the sponge. Rinse under tap water to
remove any built up which may have accumulated on
it. If the sponge shows signs of deterioration replace
it. Note: the 360 and 480 series pumps do not include
sponges.
12. Reassemble in reverse order; ensure an aquarium
safe lubricant is used to lubricate the O-ring on the
impeller cover.
13. Prior to reinstalling the unit into your aquarium or
filter, ensure your hand is dry and there is no water
on any part of the pump which is not intended to have
water on it. Plug the pump in and turn on to ensure the
pump is working corectly.
2300 - 4900 shown. Other models differ slightly, see
Know you pump for further details
11
GB
Impeller
chamber